Example 2 A CNC machine tool adopts SIEMENS 810T system. The PLC program suddenly disappears in the middle of the machine. After checking, it is found that the storage system battery has no power. After replacing the battery and transferring the PLC to the system, the machine tool can run normally. Since the SIEMENS 810T system does not have battery warning information, the SIEMENS 810T system is widely used by users.